  1. 320A Resi Pedestal Service | Information by Electrical Professionals ...

    Nov 23, 2025 · The pedestal will have a 320 amp meter socket and (2) -200 amp main breaker disconnects. (2) - 2" Seperate conduits from each disconnect to the house. Do I still need 2 …

  2. Grounding Electrode for RV Pedestal??? | Information by Electrical ...

    Feb 16, 2023 · 1st ISSUE Is a grounding electrode required for an RV pedestal that has a 50 amp breaker and receptacle with a 20 amp receptacle and breaker? If my understanding is correct …

  3. New RV park | Information by Electrical Professionals for Electrical ...

    May 13, 2021 · In regard to your initial question about breaker sizing--every RV park pedestal that I've seen had separate breakers for the 50 amp, 30 amp, and 20 amp receptacles, but since …

  4. Cutting an aluminum boat pedestal post | Michigan Sportsman …

    Apr 25, 2025 · I have a boat seat pedestal that needs cutting to shorten. It's the Springfield adjustable butt seat type post. Tried cutting it with a hacksaw and smoothing the edges but it …

  5. RV pedestals and the Tap Rule - Mike Holt's Forum

    Jun 7, 2020 · I'm designing my first RV Park. The pedestals my customer wants are offered by more than one manufacturer and are very similar. They have a 2P50A, a 1P30A, and a 1P20A …

  6. max current for RV pedestals? | Information by Electrical …

    May 7, 2019 · The key may be in the definition of "continuous load". Even though the pedestal may be loaded to the hilt, in a 3 hour period there is going to be some equipment cycle often …

  7. RV site requirements | Information by Electrical Professionals for ...

    May 9, 2016 · Is it required to have a ground rod at each 50/30/20 RV pedestal. Yes. While not always enforced 250.32 requires a grounding electrode for any building or structure supplied …

  8. 400 Amp Meter Main Pedestal | Information by Electrical …

    Jul 23, 2024 · I will be wiring a new home with a 400 amp service. The meter pedestal will be around 20 feet from the pad mounted transformer. We are responsible for the conduit and …

  9. pedestal combination meter and main | Information by Electrical ...

    Feb 3, 2005 · Re: pedestal combination meter and main George, the meter pedestal has a main disconnecting means, it is a structure, and everything downstream is being fed from a feeder …

  10. 230.71 and RV parks | Information by Electrical Professionals for ...

    Mar 16, 2023 · Each pedestal is its own structure technically, but 225 will allow up to 6 switches. 230 only applied to service equipment, but if the pedestals were suitable as service equipment …